Free Australian steel section data · AS 4100 · AS/NZS 3679 · AS/NZS 1163 DownloadsAdvertiseContact

Structural bolt capacities (AS 4100)

Design capacities of single M12 to M36 structural bolts to AS 4100:2020 in the bolting categories of Table 9.2.1: 4.6/S (AS 1111 or AS 1110 bolts), 8.8/S, 8.8/TB and 8.8/TF (AS/NZS 1252.1), and the 10.9 categories added in 2020, with ply bearing, hole sizes, pitch and edge distances.

Grade 4.6 and 8.8 bolts (one bolt, one shear plane)

Bolt4.6/S (fuf = 400 MPa) 8.8/S and 8.8/TB (fuf = 830 MPa, M12 800 MPa)8.8/TF friction
φNtf (kN)φVf N (kN)φVf X (kN)φNtf (kN)φVf N (kN)φVf X (kN) Nti (kN)φVsf (kN)
M1227.015.122.454.030.244.8––
M1650.228.639.9104.259.382.79523.3
M2078.444.662.3162.792.6129.314535.5
M24113.064.389.7234.4133.4186.121051.4
M30179.5103.0140.3372.5213.7291.133582.1
M36261.4150.6202.0542.5312.5419.1490120.0

N: threads intercept the shear plane; X: they don't (plain shank). φVf is for one shear plane with kr = 1.0; multiply by the number of shear planes. φVsf is per effective interface with μ = 0.35 (clean as-rolled surfaces) and kh = 1.0 (standard holes). S: snug tight; TB and TF: fully tensioned (Table 9.2.1). Grade 8.8 bolts less than 16 mm in diameter (M12) have fuf = 800 MPa (Table 9.2.1, Note 2).

Grade 10.9 bolts (one bolt, one shear plane)

Bolt10.9/S and 10.9/TB (fuf = 1040 MPa)10.9/TF friction
φNtf (kN)φVf N (kN)φVf X (kN)Nti (kN)φVsf (kN)
M1270.132.658.3––
M16130.661.7103.713031.8
M20203.896.3162.020550.2
M24293.7138.7233.229572.3
M30466.8222.2364.7465113.9
M36679.7325.0525.1680166.6

With threads intercepting the shear plane, grade 10.9 bolts take krd = 0.83 for their lower ductility (Cl. 9.2.2.1). Check availability and the Table 9.2.1 notes before specifying 10.9 bolts.

Ply in bearing

Design bearing capacity of the ply per millimetre of ply thickness, φVb/tp = 0.9 × 3.2dffup (kN/mm), for common ply tensile strengths fup (MPa):

Bolt410
Grade 250 plate
430
Grade 300 plate, C350L0
440
Grade 300 sections
450
Grade 350 plate
480
Grade 350 sections
500
C450L0
M1214.214.915.215.616.617.3
M1618.919.820.320.722.123.0
M2023.624.825.325.927.628.8
M2428.329.730.431.133.234.6
M3035.437.238.038.941.543.2
M3642.544.645.646.749.851.8

Tear-out near an edge also limits the ply: φVp = 0.9aetpfup, where ae is the distance from the edge of the hole to the edge of the ply, measured in the direction of the force, plus half the bolt diameter (Cl. 9.2.2.4). Use the smaller of φVb and φVp.

Holes, pitch and edge distance (mm)

BoltStandard holeOversize hole, max. Short slot, max. lengthLong slot, max. lengthMin. pitchMin. edge distance (Table 9.5.2)
Sheared or hand flame cut edgeRolled plate, flat bar or section: machine cut, sawn or planed edgeRolled edge of a rolled flat bar or section
M121420223030211815
M161824264040282420
M202228305050353025
M242632346060423630
M30333840757552.54537.5
M36394547.99090635445

Hole sizes from Cl. 14.3.2: standard holes are df + 2 mm up to M24 and df + 3 mm above; oversize holes up to the larger of 1.25df and df + 8 mm; slots are the standard hole width, with short slots up to the larger of 1.33df and df + 10 mm long and long slots up to 2.5df. Oversize and slotted holes need hardened or plate washers, and Cl. 14.3.2 limits where they may be used. Base plate holes may be up to 6 mm larger than the anchor bolt, with a plate washer at least 4 mm thick where the hole is 3 mm or more oversize. Minimum pitch is 2.5df (Cl. 9.5.1). Edge distances are measured from the centre of a standard hole; for other holes, from the nearer edge of the hole plus df/2 (Cl. 9.5.2).

Bolt areas (AS 1275, mm²)

BoltThread pitch (mm)Ao plain shankAs tensile stressAc minor diameter
M121.7511384.376.2
M162201157144
M202.5314245225
M243452353324
M303.5707561519
M3641018817759

Formulas (AS 4100:2020)

Design aid only, not a substitute for a qualified engineer or for AS 4100 itself. See the disclaimer and data sources.