Free Australian steel section data · AS 4100 · AS/NZS 3679 · AS/NZS 1163 DownloadsAdvertiseContact

Structural Bolting Guide (AS 4100)

How to choose, detail and install structural bolts in Australia: 4.6/S, 8.8/S, 8.8/TB and 8.8/TF, holes, gauges, washers, length and tightening.

Bolting categories

AS 4100 describes a bolt by its property class and how it is tightened:

CategoryBoltTighteningTypical use
4.6/SCommercial bolt, property class 4.6 (AS 1111)Snug tightLight, secondary and non-structural connections: purlin cleats, handrails, minor framing.
8.8/SHigh-strength structural bolt assembly, class 8.8 (AS/NZS 1252.1)Snug tightMost connections in simple construction: beam cleats, end plates, fin plates, splices in shear. The ASI standard connections use M20 8.8/S.
8.8/TBAs 8.8/SFully tensioned, designed in bearingConnections that need the stiffness of a tensioned joint, such as rigid (moment) end-plate connections.
8.8/TFAs 8.8/SFully tensioned, designed for frictionJoints that must not slip in service: load reversal, fatigue and vibration, and oversize or slotted holes parallel to the load.

Design capacities for each category and bolt size (shear with threads included or excluded, tension, friction, ply bearing) are on the bolt capacities page.

Bolt assemblies

Holes

Gauges, pitch and edge distance

Bolts across a flange or web should sit on the standard gauge lines, which keep them clear of the web and root radius and far enough from the flange edge. Minimum pitch is 2.5 bolt diameters, and the minimum edge distance is 1.25 to 1.75 diameters depending on how the edge was made. See the bolt gauge guide, and each UB, UC, WB, WC and PFC section page for its own gauges.

Threads in the shear plane

A bolt is stronger in shear where the plain shank crosses the shear plane than where the threads do. Unless the bolt length, thread length and ply thicknesses are controlled so the shank is in the shear plane, design with the threads included (the “N” condition). If it matters, specify which way the bolt is inserted on the drawings.

Bolt length

The bolt has to pass through the plies (the grip), the washers and the nut, with enough left over that the thread shows beyond the nut once it is tight; AS/NZS 5131 Cl 8.2 sets the thread requirements. Don't use a bolt so long that the nut runs out of thread before it clamps the plies. The bolt length calculator works out the length for a through-bolt with a nut, or for a bolt into a tapped hole.

Tightening

Further reading: ASI Technical Notes TN001 (high-strength structural bolt assemblies) and TN016 (installation of bolted connections). This guide summarises common practice; the Standards and the project specification govern.