Bolt Gauges & Edge Distances for Steel Sections
Standard bolt gauge lines for Australian UB, UC, WB, WC and PFC sections, with AS 4100 edge distances and bolt-to-web and bolt-to-edge distances.
A bolt gauge is the distance between two lines of bolts across a flange (sgf) or a web (sgw). Using the standard gauges keeps the holes far enough from the flange edge to satisfy the AS 4100 minimum edge distance, and far enough from the web and root radius that the bolt head, nut and spanner fit. Flange gauges are measured centre to centre across the web; for channels, from the back of the web to the bolt.
The values below are the standard gauges from the Australian Steel Institute connection series (ASI, Steel Construction Vol 41 No 2), first preference first. For each universal section the distances from the bolt centre to the flange edge and to the face of the web are worked out from its dimensions at the preferred M20 gauge. Every section page also lists its own gauges.
Minimum distances (AS 4100)
- Edge distance, from the hole centre (Table 9.5.2): 1.75df to a sheared or hand flame-cut edge, 1.5df to a machine-cut, sawn or planed edge, and 1.25df to the rolled edge of a flat bar or section. For an M20 bolt: 35, 30 and 25 mm.
- Pitch (centre to centre along a line): at least 2.5df, 50 mm for M20 (Cl 9.5.1).
- Clearance to the web: no single figure in the Standard; it has to leave room for the root radius, the nut or bolt head and the spanner or tensioning tool. The standard gauges below already allow for this.
Full hole sizes, slot limits and edge distances for every bolt size are on the bolt capacities page.
Universal beams
| Section | bf | tw | Flange sgf M20 | Bolt to flange edge | Bolt to web face | Flange sgf M24 | Web sgw M20/M24 |
|---|---|---|---|---|---|---|---|
| 610UB125 | 229 | 11.9 | 140, 90 | 44.5 | 64.0 | 140, 90 | 140, 90, 70 |
| 610UB113 | 228 | 11.2 | 140, 90 | 44.0 | 64.4 | 140, 90 | 140, 90, 70 |
| 610UB101 | 228 | 10.6 | 140, 90 | 44.0 | 64.7 | 140, 90 | 140, 90, 70 |
| 530UB92.4 | 209 | 10.2 | 140, 90 | 34.5 | 64.9 | 140, 90 | 140, 90, 70 |
| 530UB82.0 | 209 | 9.6 | 140, 90 | 34.5 | 65.2 | 140, 90 | 140, 90, 70 |
| 460UB82.1 | 191 | 9.9 | 90, 140 | 50.5 | 40.0 | 90 | 90, 70, 140 |
| 460UB74.6 | 190 | 9.1 | 90, 140 | 50.0 | 40.5 | 90 | 90, 70, 140 |
| 460UB67.1 | 190 | 8.5 | 90, 140 | 50.0 | 40.8 | 90 | 90, 70, 140 |
| 410UB59.7 | 178 | 7.8 | 90, 70 | 44.0 | 41.1 | 90 | 90, 70, 140 |
| 410UB53.7 | 178 | 7.6 | 90, 70 | 44.0 | 41.2 | 90 | 90, 70, 140 |
| 360UB56.7 | 172 | 8 | 90, 70 | 41.0 | 41.0 | 90 | 90, 70, 140 |
| 360UB50.7 | 171 | 7.3 | 90, 70 | 40.5 | 41.4 | 90 | 90, 70, 140 |
| 360UB44.7 | 171 | 6.9 | 90, 70 | 40.5 | 41.5 | 90 | 90, 70, 140 |
| 310UB46.2 | 166 | 6.7 | 90, 70 | 38.0 | 41.6 | 90 | 90, 70, 140 |
| 310UB40.4 | 165 | 6.1 | 90, 70 | 37.5 | 42.0 | 90 | 90, 70, 140 |
| 310UB32.0 | 149 | 5.5 | 70 | 39.5 | 32.2 | – | 90, 70, 140 |
| 250UB37.3 | 146 | 6.4 | 70, 90 | 38.0 | 31.8 | – | 70, 90, 140 |
| 250UB31.4 | 146 | 6.1 | 70, 90 | 38.0 | 31.9 | – | 70, 90, 140 |
| 250UB25.7 | 124 | 5 | 70 | 27.0 | 32.5 | – | 70, 90, 140 |
| 200UB29.8 | 134 | 6.3 | 70 | 32.0 | 31.9 | – | 70, 90 |
| 200UB25.4 | 133 | 5.8 | 70 | 31.5 | 32.1 | – | 70, 90 |
| 200UB22.3 | 133 | 5 | 70 | 31.5 | 32.5 | – | 70, 90 |
| 200UB18.2 | 99 | 4.5 | 50 | 24.5 | 22.8 | – | 70, 90 |
| 180UB22.2 | 90 | 6 | –b | – | – | – | 70, 90 |
| 180UB18.1 | 90 | 5 | –b | – | – | – | 70, 90 |
| 180UB16.1 | 90 | 4.5 | –b | – | – | – | 70, 90 |
| 150UB18.0 | 75 | 6 | –b | – | – | – | 70 |
| 150UB14.0 | 75 | 5 | –b | – | – | – | 70 |
Universal columns
| Section | bf | tw | Flange sgf M20 | Bolt to flange edge | Bolt to web face | Flange sgf M24 | Web sgw M20/M24 |
|---|---|---|---|---|---|---|---|
| 310UC158 | 311 | 15.7 | 140, 90 | 85.5 | 62.1 | 140, 90 | 90, 70, 140 |
| 310UC137 | 309 | 13.8 | 140, 90 | 84.5 | 63.1 | 140, 90 | 90, 70, 140 |
| 310UC118 | 307 | 11.9 | 140, 90 | 83.5 | 64.0 | 140, 90 | 90, 70, 140 |
| 310UC96.8 | 305 | 9.9 | 140, 90 | 82.5 | 65.0 | 140, 90 | 90, 70, 140 |
| 250UC89.5 | 256 | 10.5 | 140, 90 | 58.0 | 64.8 | 140, 90 | 90, 70, 140 |
| 250UC72.9 | 254 | 8.6 | 140, 90 | 57.0 | 65.7 | 140, 90 | 90, 70, 140 |
| 200UC59.5 | 205 | 9.3 | 140, 90 | 32.5 | 65.3 | 140, 90 | 90, 70 |
| 200UC52.2 | 204 | 8 | 140, 90 | 32.0 | 66.0 | 140, 90 | 90, 70 |
| 200UC46.2 | 203 | 7.3 | 140, 90 | 31.5 | 66.3 | 140, 90 | 90, 70 |
| 150UC37.2 | 154 | 8.1 | 90, 70 | 32.0 | 41.0 | 90 | 70 |
| 150UC30.0 | 153 | 6.6 | 90, 70 | 31.5 | 41.7 | 90 | 70 |
| 150UC23.4 | 152 | 6.1 | 90, 70 | 31.0 | 42.0 | 90 | 70 |
| 100UC14.8 | 99 | 5 | 60 | 19.5 | 27.5 | –b | –c |
–b: the flange will not take this bolt size. –c: the web will not take two lines of bolts at a gauge of 50 mm or more. The flange gauges for 250UB25.7 and 200UB18.2 are for M16 bolts. Dimensions in mm.
Welded beams and columns
| Section | M20 sgf1 | M20 sgf2 (outer pair) | M24 sgf1 | M24 sgf2 (outer pair) |
|---|---|---|---|---|
| 1200WB 455/423/392 | 140, 90 | 280, 420 | 140, 90 | 280 |
| 1200WB 342/317/278 | 140, 90 | 280 | 140, 90 | 280 |
| 1200WB 249 | 140, 90 | – | 140, 90 | – |
| 1000WB 322/296/258 | 140, 90 | 280 | 140, 90 | 280 |
| 1000WB 215 | 140, 90 | – | 140, 90 | – |
| 900WB 282/218 | 140, 90 | 280 | 140, 90 | 280 |
| 900WB 175 | 140, 90 | – | 140, 90 | – |
| 800WB | 140, 90 | – | 140, 90 | – |
| 700WB | 140, 90 | – | 140, 90 | – |
| 500WC | 140 | 280, 420 | 140 | 280 |
| 400WC | 140 | 280 | 140 | 280 |
| 350WC | 140 | – | 140 | – |
Wide welded flanges can take a second, outer pair of bolts at sgf2. Web gauges for all welded sections: 140, 90 or 70 mm (M20 and M24). Dimensions in mm.
Parallel flange channels
| Section | Flange M16 | Flange M20 | Flange M24 | Web M16 | Web M20 | Web M24 |
|---|---|---|---|---|---|---|
| 380PFC | 55 | 55 | 55 | 140, 90, 70 | 140, 90, 70 | 140, 90, 70 |
| 300PFC | 55 | 55 | –b | 140, 90, 70 | 140, 90, 70 | 140, 90, 70 |
| 250PFC | 55 | 55 | –b | 140, 90, 70 | 140, 90, 70 | 140, 90, 70 |
| 230PFC | 45 | 45 | –b | 140, 90, 70 | 90, 70 | 90, 70 |
| 200PFC | 45 | 45 | –b | 90, 70 | 90, 70 | 90, 70 |
| 180PFC | 45 | 45 | –b | 70, 90 | 70, 90 | 70 |
| 150PFC | 45 | 45 | –b | 70 | 65 | 55 |
Channel flange gauges are from the back of the web to the bolt line. Dimensions in mm.
See also the bolting guide and the bolt length calculator.