Fillet weld capacities (AS 4100)
Design capacity per millimetre of length of equal-leg fillet welds to AS 4100:2020, for SP and GP weld categories and the weld metal strengths of Table 9.6.3.10(A). Welding to AS/NZS 1554.1 (Cl. 9.6.1.1).
| Leg tw (mm) | Throat tt (mm) | E43XX / W40X SP fuw = 430 MPa, φ = 0.8 | E43XX / W40X GP fuw = 430 MPa, φ = 0.6 | E49XX / W50X SP fuw = 490 MPa, φ = 0.8 | E49XX / W50X GP fuw = 490 MPa, φ = 0.6 | E55XX / W55X SP fuw = 550 MPa, φ = 0.8 | E55XX / W55X GP fuw = 550 MPa, φ = 0.6 |
|---|---|---|---|---|---|---|---|
| 3 | 2.12 | 0.438 | 0.328 | 0.499 | 0.374 | 0.560 | 0.420 |
| 4 | 2.83 | 0.584 | 0.438 | 0.665 | 0.499 | 0.747 | 0.560 |
| 5 | 3.54 | 0.730 | 0.547 | 0.832 | 0.624 | 0.933 | 0.700 |
| 6 | 4.24 | 0.876 | 0.657 | 0.998 | 0.748 | 1.120 | 0.840 |
| 8 | 5.66 | 1.168 | 0.876 | 1.330 | 0.998 | 1.493 | 1.120 |
| 10 | 7.07 | 1.459 | 1.095 | 1.663 | 1.247 | 1.867 | 1.400 |
| 12 | 8.49 | 1.751 | 1.314 | 1.996 | 1.497 | 2.240 | 1.680 |
| 16 | 11.31 | 2.335 | 1.751 | 2.661 | 1.996 | 2.987 | 2.240 |
Values are φvw in kN per mm of weld length, with kr = 1.0. Example: two 200 mm runs of 6 mm E49XX SP fillet weld carry 2 × 200 × 0.998 = 399 kN. E49XX (W50X for submerged arc) is the usual match for Grade 300 and 350 steel; the 2020 edition gives it fuw = 490 MPa, where the 1998 edition used 480 MPa for E48XX.
Formulas (AS 4100:2020)
- Fillet weld (Cl. 9.6.3.10): φvw = φ0.6fuwttkr, with fuw from Table 9.6.3.10(A) and φ = 0.8 for SP and 0.6 for GP welds (Table 3.4). Longitudinal fillet welds on RHS thinner than 3 mm use φ = 0.7 (SP only). For an equal-leg fillet the design throat thickness tt = tw/√2.
- Design force: v*w is the vector sum of the design forces per unit length on the effective area of the weld. Weld groups are covered by Cl. 9.7.
- Long welds in lap connections: kr = 1.0 for lw ≤ 1.7 m, 1.10 − 0.06lw for 1.7 < lw ≤ 8 m and 0.62 beyond (Table 9.6.3.10(B)); other connections use kr = 1.0.
- Weld metal strength (Table 9.6.3.10(A)): 430 MPa for E43XX/W40X consumables, 490 MPa for E49XX/W50X and 550 MPa for E55XX/W55X, with equivalent flux cored, gas metal arc and gas tungsten arc classifications. Higher strengths (up to 830 MPa) apply to quenched and tempered steels welded to AS/NZS 1554.4.
- Butt welds: complete penetration butt welds use φ = 0.9 for SP and 0.6 for GP (Cl. 9.6.2.7, Table 3.4); incomplete penetration butt welds use the fillet weld factors.
- Categories: SP (structural purpose) and GP (general purpose) welds are defined in AS/NZS 1554.1; GP welds use the lower capacity factor.
Design aid only, not a substitute for a qualified engineer or for AS 4100 itself. See the disclaimer and data sources.