Australian section designations follow a consistent pattern: size, then section type, then mass or thickness.

DesignationRead as
310UB40.4Nominal depth 310 mm, universal beam, 40.4 kg/m (actual depth 304 mm)
200UC52.2Nominal depth 200 mm, universal column, 52.2 kg/m
150PFC150 mm deep parallel flange channel (one mass per depth, so no mass in the name)
800WB168Nominal depth 800 mm, welded beam, 168 kg/m
75x75x6EA75 × 75 mm legs, nominal 6 mm thick, equal angle
150x90x10UA150 × 90 mm legs, nominal 10 mm (actual 9.5 mm), unequal angle
100x100x5.0SHS100 × 100 mm outside, 5.0 mm wall, square hollow section
150x50x3.0RHS150 mm deep × 50 mm wide, 3.0 mm wall
168.3x7.1CHS168.3 mm outside diameter, 7.1 mm wall
155BT20.2Tee 155 mm nominal depth cut from a 310UB40.4 (half its mass)
C20019Cee purlin, 200 series (203 mm deep), 1.9 mm base metal thickness
100x10FL100 mm wide × 10 mm thick flat bar

Nominal vs actual dimensions

For UB, UC and WB sections the leading number is a nominal depth that groups sections rolled with the same rolls. The actual depth varies with mass: the 310UB32.0, 310UB40.4 and 310UB46.2 are 298, 304 and 307 mm deep. Always detail from the actual dimensions. Several angle thicknesses are also nominal: "8" is 7.8 mm, "10" is 9.5 mm and "16" is 15.8 mm.

Older designations

Older drawings may show spaced or rounded designations such as "310 UB 40" (today's 310UB40.4), or imperial BHP sections. Match on the actual dimensions and mass rather than the label, and check sections that are no longer rolled against historical tables before reusing old calculations.