Free Australian steel section data · AS 4100 · AS/NZS 3679 · AS/NZS 1163 DownloadsAdvertiseContact

20x20x1.6SHS Square Hollow Section

AS/NZS 1163Grade C450L0
Mass
0.87 kg/m
Size
20 × 20 mm
Wall t
1.6 mm
Corner radius ro
3.2 mm
Area Ag
111 mm²
Ix
0.00608 ×10⁶ mm⁴
Iy
0.00608 ×10⁶ mm⁴
Zx
0.608 ×10³ mm³
φMsx (Grade C450L0)
0.3 kNm

Also written as: 20 x 20 x 1.6 SHS, 20x20x1.6 SHS, 20 x 1.6 SHS

DXFSVG drawingJSON data
20x20x1.6SHS Square Hollow Section cross-section drawingd = 20b = 20t = 1.6xxyyro = 3.2NOTES1. ALL DIMENSIONS IN MILLIMETRES. TRUE SCALE 5:1 WHEN PRINTED ON A4.2. x-x, y-y: CENTROIDAL (PRINCIPAL) AXES.3. VERIFY AGAINST MANUFACTURER DATA BEFORE USE.STEELINFOSTEELINFO.AUTITLE20x20x1.6SHS SQUARE HOLLOW SECTIONSTANDARDAS/NZS 1163GRADEC450L0SCALE @ A45:1UNITSmmDATE2026-10-08

Open the full A4 drawing sheet (pinch to zoom)

Dimensions

20x20x1.6SHS dimensions
SymbolPropertyValueUnit
dDepth20mm
bWidth20mm
tWall thickness1.6mm
roExternal corner radius (used for properties)3.2mm

Section properties

20x20x1.6SHS section properties
SymbolPropertyValueUnit
mMass per metre (nominal)0.87kg/m
AgGross cross-section area111mm²
IxSecond moment of area about x-axis0.0060810⁶ mm⁴
ZxElastic section modulus, x-axis0.60810³ mm³
SxPlastic section modulus, x-axis0.75110³ mm³
rxRadius of gyration, x-axis7.4mm
IySecond moment of area about y-axis0.0060810⁶ mm⁴
ZyElastic section modulus, y-axis0.60810³ mm³
SyPlastic section modulus, y-axis0.75110³ mm³
ryRadius of gyration, y-axis7.4mm
JTorsion constant10.310³ mm⁴
CTorsion modulus0.92410³ mm³
AsExternal surface area per metre0.075m²/m
As/tExternal surface area per tonne85.3m²/t

Axes: x-x is the major axis and y-y the minor axis, both through the centroid.

Mass 5.2 kg · surface area 0.45 m²

Design capacities to AS 4100

AS 4100 design capacities – Grade C450L0
SymbolPropertyValueUnit
Steel gradeC450L0 (AS/NZS 1163)
fyYield stress used450MPa
fuTensile strength500MPa
kfForm factor (Cl. 6.2.2)1.000
Section class, x-axis (Cl. 5.2)Compact
ZexEffective section modulus, x-axis0.75110³ mm³
φMsxSection moment capacity, x-axis0.3kNm
Section class, y-axisCompact
ZeyEffective section modulus, y-axis0.75110³ mm³
φMsySection moment capacity, y-axis0.3kNm
φNsSection compression capacity (Cl. 6.2.1)45kN
φNtTension capacity, gross section (Cl. 7.2, kt=1, An=Ag)43kN
φVvShear capacity (Cl. 5.11)13kN
αbCompression member section constant (Table 6.3.3)-0.5
Member capacity vs effective length (αm = 1.0)
Le (m)φNcx (kN)φNcy (kN)
0.530.130.1
110.010.0
1.54.64.6
22.62.6
2.51.71.7
31.21.2
3.50.90.9
40.70.7
50.40.4
60.30.3
70.20.2
80.20.2
90.10.1
100.10.1
120.10.1

φNc: Cl. 6.3.3, pin-ended effective length Le = keL, concentric load.

3326201370024681012Effective length Le (m)
φNcx (kN)φNcy (kN)
Member capacity calculator

Check it for a span and loads with the beam calculator.

For restraint types, ktklkr and αm, use the lateral restraint calculator.

Instant check only. Effective lengths and moment modification factors must be determined by the designer in accordance with AS 4100 Cl. 4.6, 5.6.3 and 6.3.2. Not a substitute for a qualified engineer: see the disclaimer.

Other square hollow sections

Numbers are the thickness in mm.

400 × 400 SHS16.0 12.5 10.0
350 × 350 SHS16.0 12.5 10.0 8.0
300 × 300 SHS16.0 12.5 10.0 8.0
250 × 250 SHS16.0 12.5 10.0 9.0 8.0 6.0
200 × 200 SHS16.0 12.5 10.0 9.0 8.0 6.0 5.0
150 × 150 SHS10.0 9.0 8.0 6.0 5.0
125 × 125 SHS10.0 9.0 8.0 6.0 5.0 4.0
100 × 100 SHS10.0 9.0 8.0 6.0 5.0 4.0 3.0 2.5
90 × 90 SHS2.5 2.0
89 × 89 SHS6.0 5.0 3.5 2.0
75 × 75 SHS6.0 5.0 4.0 3.5 3.0 2.5 2.0
65 × 65 SHS6.0 5.0 4.0 3.0 2.5 2.0 1.6
50 × 50 SHS6.0 5.0 4.0 3.0 2.5 2.0 1.6
40 × 40 SHS4.0 3.0 2.5 2.0 1.6
35 × 35 SHS3.0 2.5 2.0 1.6
30 × 30 SHS3.0 2.5 2.0 1.6
25 × 25 SHS3.0 2.5 2.0 1.6
20 × 20 SHS2.0 1.6

Relevant Australian Standards

See all Australian Standards for structural steel.

Properties are calculated from nominal dimensions, including root and toe radii, as described in notation & method. Mass is the nominal catalogue mass; the calculated mass at 7850 kg/m³ is 0.87 kg/m. Verify against current manufacturer literature before use in design. Spotted an error? Report it.