Free Australian steel section data · AS 4100 · AS/NZS 3679 · AS/NZS 1163 DownloadsAdvertiseContact

100TFB Taper Flange Beam

AS/NZS 3679.1Grade 300

The 100TFB is a taper flange beam to AS/NZS 3679.1. It is 100 mm deep with a 45 mm wide flange, has a mass of 7.20 kg/m and a gross area of 917 mm². Its major-axis second moment of area is Ix = 1.46 × 10⁶ mm⁴ and in Grade 300 (fy = 320 MPa) its section moment capacity is φMsx = 9.8 kNm. Download its free DXF drawing (a true-scale CAD outline) below, or print the dimensioned drawing sheet.

Also written as: 100 TFB

DXF (AutoCAD R12)SVG drawingJSON data
100TFB Taper Flange Beam cross-section drawingxxyyd = 100bf = 45tf = 6SLOPE 8°tw = 4r1 = 7NOTES1. ALL DIMENSIONS IN MILLIMETRES. TRUE SCALE 1:1 WHEN PRINTED ON A4.2. x-x, y-y: CENTROIDAL (PRINCIPAL) AXES.3. VERIFY AGAINST MANUFACTURER DATA BEFORE USE.STEELINFOSTEELINFO.AUTITLE100TFB TAPER FLANGE BEAMSTANDARDAS/NZS 3679.1GRADE300SCALE @ A41:1UNITSmmDATE2026-10-08

Open the drawing full size (pinch to zoom)

Dimensions

100TFB dimensions
SymbolPropertyValueUnit
dDepth of section100mm
bfFlange width45mm
tfFlange thickness (at mid-outstand)6.0mm
twWeb thickness4.0mm
r1Root radius7.0mm
r2Toe radius3.0mm
Flange slope (inner face)8.0°
d1Clear web depth (d − 2tf)88mm

Section properties

100TFB section properties
SymbolPropertyValueUnit
mMass per metre (nominal)7.20kg/m
AgGross cross-section area917mm²
IxSecond moment of area about x-axis1.4610⁶ mm⁴
ZxElastic section modulus, x-axis29.210³ mm³
SxPlastic section modulus, x-axis34.110³ mm³
rxRadius of gyration, x-axis39.9mm
IySecond moment of area about y-axis0.079410⁶ mm⁴
ZyElastic section modulus, y-axis3.5310³ mm³
SyPlastic section modulus, y-axis6.0010³ mm³
ryRadius of gyration, y-axis9.3mm
JTorsion constant8.3610³ mm⁴
IwWarping constant0.17510⁹ mm⁶
AsExternal surface area per metre0.349m²/m
As/tExternal surface area per tonne48.5m²/t

Axes: x-x is the major axis and y-y the minor axis, both through the centroid.

Mass 43.2 kg · surface area 2.09 m²

Design capacities to AS 4100

AS 4100 design capacities – Grade 300
SymbolPropertyValueUnit
Steel grade300 (AS/NZS 3679.1)
fyYield stress used320MPa
fuTensile strength440MPa
kfForm factor (Cl. 6.2.2)1.000
Section class, x-axis (Cl. 5.2)Compact
ZexEffective section modulus, x-axis34.110³ mm³
φMsxSection moment capacity, x-axis9.8kNm
Section class, y-axisCompact
ZeyEffective section modulus, y-axis5.2910³ mm³
φMsySection moment capacity, y-axis1.5kNm
φNsSection compression capacity (Cl. 6.2.1)264kN
φNtTension capacity, gross section (Cl. 7.2, kt=1, An=Ag)264kN
φVvShear capacity (Cl. 5.11)69kN
αbCompression member section constant (Table 6.3.3)0.5
Member capacity vs effective length (αm = 1.0)
Le (m)φMbx (kNm)φNcx (kN)φNcy (kN)
0.58.6263196
16.324499.2
1.54.822552.2
23.820231.4
2.53.117820.8
32.715314.8
3.52.312911.0
42.01098.5
51.678.85.5
61.458.63.9
71.245.02.9
81.035.52.2
90.928.71.7
100.823.61.4
120.716.81.0

φMbx: AS 4100 Cl. 5.6.1.1 with αm = 1.0; Le = ktklkrL. φNc: Cl. 6.3.3, pin-ended effective length Le = keL, concentric load.

928472276170411425700024681012Effective length Le (m)
φMbx (kNm)φNcx (kN)φNcy (kN) Left axis kNm, right axis kN.
Member capacity calculator

Check it for a span and loads with the beam calculator.

For restraint types, ktklkr and αm, use the lateral restraint calculator.

Instant check only. Effective lengths and moment modification factors must be determined by the designer in accordance with AS 4100 Cl. 4.6, 5.6.3 and 6.3.2. Not a substitute for a qualified engineer: see the disclaimer.

Alternatives with similar bending capacity

Sections from other families with a plastic modulus Sx within −8% / +25% of the 100TFB, lightest first.

SectionTypeMass (kg/m)Sx (10³ mm³)Ix (10⁶ mm⁴)
150x50x2.0RHSRectangular Hollow Section6.0735.32.08
125x75x2.0RHSRectangular Hollow Section6.0732.51.69
125x75x2.5RHSRectangular Hollow Section7.5340.02.07
100x100x2.5SHSSquare Hollow Section7.5334.91.51
100PFCParallel Flange Channel8.3340.31.74
100x50x4.0RHSRectangular Hollow Section8.4933.41.31

Other taper flange beams

Relevant Australian Standards

See all Australian Standards for structural steel.

Properties are calculated from nominal dimensions, including root and toe radii, as described in notation & method. Mass is the nominal catalogue mass; the calculated mass at 7850 kg/m³ is 7.20 kg/m. Verify against current manufacturer literature before use in design. Spotted an error? Report it.