Free Australian steel section data · AS 4100 · AS/NZS 3679 · AS/NZS 1163 DownloadsAdvertiseContact

155CT59.0 Column Tee (cut from UC)

Cut from AS/NZS 3679.1 UCGrade 300
Mass
59.0 kg/m
Size
157.5 × 307 mm
Flange tf
18.7 mm
Web tw
11.9 mm
Root radius r1
16.5 mm
Area Ag
7510 mm²
Ix
10.8 ×10⁶ mm⁴
Iy
45.1 ×10⁶ mm⁴
Zx (min.)
82.5 ×10³ mm³
Cut from
310UC118

Also written as: 155 CT 59.0, 155CT59, 155 CT 59

DXFSVG drawingJSON data
155CT59.0 Column Tee (cut from UC) cross-section drawingd = 157.5bf = 307tf = 18.7tw = 11.9yc = 26.9xxyyNOTES1. ALL DIMENSIONS IN MILLIMETRES. TRUE SCALE 1:2 WHEN PRINTED ON A4.2. x-x, y-y: CENTROIDAL (PRINCIPAL) AXES.3. VERIFY AGAINST MANUFACTURER DATA BEFORE USE.STEELINFOSTEELINFO.AUTITLE155CT59.0 COLUMN TEE (CUT FROM UC)STANDARDAS/NZS 3679.1GRADE300SCALE @ A41:2UNITSmmDATE2026-10-08

Open the full A4 drawing sheet (pinch to zoom)

Dimensions

155CT59.0 dimensions
SymbolPropertyValueUnit
dDepth of tee157.5mm
bfFlange width307mm
tfFlange thickness18.7mm
twStem thickness11.9mm
r1Root radius16.5mm

Section properties

155CT59.0 section properties
SymbolPropertyValueUnit
mMass per metre (nominal)59.0kg/m
AgGross cross-section area7510mm²
IxSecond moment of area about x-axis10.810⁶ mm⁴
ZxElastic section modulus, x-axis (stem tip)82.510³ mm³
ZxfElastic section modulus, x-axis (flange)40110³ mm³
SxPlastic section modulus, x-axis15610³ mm³
rxRadius of gyration, x-axis37.9mm
IySecond moment of area about y-axis45.110⁶ mm⁴
ZyElastic section modulus, y-axis29410³ mm³
SyPlastic section modulus, y-axis44710³ mm³
ryRadius of gyration, y-axis77.5mm
ycCentroid from top of flange26.9mm
JTorsion constant74710³ mm⁴
AsExternal surface area per metre0.915m²/m
As/tExternal surface area per tonne15.5m²/t

Axes: x-x (major) and y-y through the centroid. yc is measured from the top of the flange.

Mass 354.0 kg · surface area 5.49 m²

Design capacities to AS 4100

AS 4100 design capacities – Grade 300
SymbolPropertyValueUnit
Steel grade300 (AS/NZS 3679.1)
fyYield stress used280MPa
fuTensile strength440MPa
kfForm factor (Cl. 6.2.2)1.000
φNsSection compression capacity (Cl. 6.2.1)1892kN
φNtTension capacity, gross section (Cl. 7.2, kt=1, An=Ag)1892kN
αbCompression member section constant (Table 6.3.3)0.5
Member capacity vs effective length (αm = 1.0)
Le (m)φNcx (kN)φNcy (kN)
0.518881892
117551891
1.516161826
214611761
2.512891695
311111626
3.59431553
47981476
55781309
64311134
7331969
8262823
9212700
10174599
12124448

φNc: Cl. 6.3.3, pin-ended effective length Le = keL, concentric load.

2044163512268184090024681012Effective length Le (m)
φNcx (kN)φNcy (kN)
Member capacity calculator

For restraint types, ktklkr and αm, use the lateral restraint calculator.

Instant check only. Effective lengths and moment modification factors must be determined by the designer in accordance with AS 4100 Cl. 4.6, 5.6.3 and 6.3.2. Not a substitute for a qualified engineer: see the disclaimer.

Other column tees (ct)

Numbers are the mass in kg/m.

155CT79.0 68.5 59.0 48.4
125CT44.8 36.5
100CT29.8 26.1 23.1
75CT18.6 15.0 11.7
50CT7.4

Relevant Australian Standards

See all Australian Standards for structural steel.

Properties are calculated from nominal dimensions, including root and toe radii, as described in notation & method. Mass is the nominal catalogue mass; the calculated mass at 7850 kg/m³ is 58.95 kg/m. Verify against current manufacturer literature before use in design. Spotted an error? Report it.