Free Australian steel section data · AS 4100 · AS/NZS 3679 · AS/NZS 1163 DownloadsAdvertiseContact

155CT79.0 Column Tee (cut from UC)

Cut from AS/NZS 3679.1 UCGrade 300
Mass
79.0 kg/m
Size
163.5 × 311 mm
Flange tf
25 mm
Web tw
15.7 mm
Root radius r1
16.5 mm
Area Ag
10066 mm²
Ix
15.2 ×10⁶ mm⁴
Iy
62.7 ×10⁶ mm⁴
Zx (min.)
114 ×10³ mm³
Cut from
310UC158

Also written as: 155 CT 79.0, 155CT79, 155 CT 79

DXFSVG drawingJSON data
155CT79.0 Column Tee (cut from UC) cross-section drawingd = 163.5bf = 311tf = 25tw = 15.7yc = 30.3xxyyNOTES1. ALL DIMENSIONS IN MILLIMETRES. TRUE SCALE 1:2 WHEN PRINTED ON A4.2. x-x, y-y: CENTROIDAL (PRINCIPAL) AXES.3. VERIFY AGAINST MANUFACTURER DATA BEFORE USE.STEELINFOSTEELINFO.AUTITLE155CT79.0 COLUMN TEE (CUT FROM UC)STANDARDAS/NZS 3679.1GRADE300SCALE @ A41:2UNITSmmDATE2026-10-08

Open the full A4 drawing sheet (pinch to zoom)

Dimensions

155CT79.0 dimensions
SymbolPropertyValueUnit
dDepth of tee163.5mm
bfFlange width311mm
tfFlange thickness25mm
twStem thickness15.7mm
r1Root radius16.5mm

Section properties

155CT79.0 section properties
SymbolPropertyValueUnit
mMass per metre (nominal)79.0kg/m
AgGross cross-section area10066mm²
IxSecond moment of area about x-axis15.210⁶ mm⁴
ZxElastic section modulus, x-axis (stem tip)11410³ mm³
ZxfElastic section modulus, x-axis (flange)50210³ mm³
SxPlastic section modulus, x-axis22410³ mm³
rxRadius of gyration, x-axis38.9mm
IySecond moment of area about y-axis62.710⁶ mm⁴
ZyElastic section modulus, y-axis40310³ mm³
SyPlastic section modulus, y-axis61410³ mm³
ryRadius of gyration, y-axis78.9mm
ycCentroid from top of flange30.3mm
JTorsion constant179810³ mm⁴
AsExternal surface area per metre0.935m²/m
As/tExternal surface area per tonne11.8m²/t

Axes: x-x (major) and y-y through the centroid. yc is measured from the top of the flange.

Mass 474.0 kg · surface area 5.61 m²

Design capacities to AS 4100

AS 4100 design capacities – Grade 300
SymbolPropertyValueUnit
Steel grade300 (AS/NZS 3679.1)
fyYield stress used280MPa
fuTensile strength440MPa
kfForm factor (Cl. 6.2.2)1.000
φNsSection compression capacity (Cl. 6.2.1)2537kN
φNtTension capacity, gross section (Cl. 7.2, kt=1, An=Ag)2537kN
αbCompression member section constant (Table 6.3.3)0.5
Member capacity vs effective length (αm = 1.0)
Le (m)φNcx (kN)φNcy (kN)
0.525352537
123622537
1.521822453
219822367
2.517592280
315262190
3.513042095
411081994
58071776
66041546
74651325
83681129
9298963
10245825
12175618

φNc: Cl. 6.3.3, pin-ended effective length Le = keL, concentric load.

27402192164410965480024681012Effective length Le (m)
φNcx (kN)φNcy (kN)
Member capacity calculator

For restraint types, ktklkr and αm, use the lateral restraint calculator.

Instant check only. Effective lengths and moment modification factors must be determined by the designer in accordance with AS 4100 Cl. 4.6, 5.6.3 and 6.3.2. Not a substitute for a qualified engineer: see the disclaimer.

Other column tees (ct)

Numbers are the mass in kg/m.

155CT79.0 68.5 59.0 48.4
125CT44.8 36.5
100CT29.8 26.1 23.1
75CT18.6 15.0 11.7
50CT7.4

Relevant Australian Standards

See all Australian Standards for structural steel.

Properties are calculated from nominal dimensions, including root and toe radii, as described in notation & method. Mass is the nominal catalogue mass; the calculated mass at 7850 kg/m³ is 79.02 kg/m. Verify against current manufacturer literature before use in design. Spotted an error? Report it.